ECM S10

Partition Sensor Set
Key Features
  • Partition sensor set that automates system behavior based on the position of a moveable wall within divisible rooms
  • eBUS port
  • Digital output
  • 14VDC output on receiver is used to power the transmitter
  • DIP switches are used to set unique eBUS device addresses and minimize setup time
  • eBUS-enabled receiver connects to the control processor using a single cable that carries both power and communication
The Extron ECM S10
Model Version Description Part #
 ECM S10 Partition Sensor 60-1705-03

The Extron ECM S10 is a partition sensor set designed to automate AV system behavior based on the position of a movable wall. The set connects to any Extron Pro Series device equipped with a digital I/O or eBUS port. It uses an infrared beam to sense the position of a movable partition wall within divisible rooms. The ECM S10 receiver offers a digital output port and a 14 VDC output to provide power to the transmitter. For convenient integration, eBUS control modules, like the ECM S10 are linked to the control processor or to other eBUS devices using a single cable that carries both power and communication. The ECM S10 transmitter and receiver each mount into a US single gang, EU, or MK junction box and include white oversized decorator-style wallplates.

Features

  • Partition sensor set that automates system behavior based on the position of a moveable wall within divisible rooms
  • eBUS port — Allows for easy connection to an eBUS device or IPCP Pro control processor.
  • Digital output — Allows for integration with non-eBUS compatible systems that have digital I/O ports.
  • 14VDC output on receiver is used to power the transmitter
  • DIP switches are used to set unique eBUS device addresses and minimize setup time
  • eBUS-enabled receiver connects to the control processor using a single cable that carries both power and communication
  • Compatible with all Extron IPCP Pro control processors and other products featuring a digital I/O
  • Various eBUS diagnostic LEDs provide connection, communication, and ID status for troubleshooting
  • Receiver module has adjustable sensitivity and logic output state controls
  • Removable captive screw connectors allow for quick installation
  • Transmitter and Receiver can be positioned up to 10 feet (3 meters) apart
  • Includes two white oversized decorator-style wallplates and mud rings
  • Mounts in US single gang, EU, or MK junction boxes
COMPATIBLE PRODUCTS
  IPCP Pro 255 IP Link Pro Control Processor
  IPCP Pro 350 IP Link Pro Control Processor
  IPCP Pro 355DR IP Link Pro Control Processor - DIN Rail
  IPCP Pro 360 IP Link Pro Control Processor
  IPCP Pro 550 IP Link Pro Control Processor
  IPCP Pro 555 IP Link Pro Control Processor
  IPCP Pro PCS1 IP Link Pro Power and Device Control Processor
  MLC Plus 84 D MediaLink Plus Controller - Decorator-Style Wallplate
  MLC Plus 84 EU MediaLink Plus Controller - EU Wallplate
  MLC Plus 84 MK MediaLink Plus Controller - MK Wallplate
  MLC Plus 50 MediaLink Plus Controller
  MLC Plus 100 MediaLink Plus Controller
  MLC Plus 100 AAP MediaLink Plus Controller with AAP Opening
  MLC Plus 200 MediaLink Plus Controller
  MLC Plus 200 AAP MediaLink Plus Controller with AAP Opening
OPTIONAL ACCESSORIES
  EWB Series External Wall Boxes

Specifications

ECM S10
eBUS control interface
   eBUS control (1) 3.5 mm captive screw connectors, 4 pole
   eBUS pin configuration +V = +12 VDC; +S = + signal; -S = - signal; G = ground
   Recommended cable type Extron STP20-2/1000 or STP20-2P/1000 cable
   Maximum system cable length 1000 feet (305 meters) sum total for the eBUS system, regardless of topology. Power injection may be required depending on system cabling topology and primary power supply wattage. See the ECM S10 Setup Guide or eBUS Technology Reference Guide for details.
ECM S10 — Receiver
   Digital output 
      Connectors (1) 3.5 mm captive screw connectors, 2 pole
      Low logic 0 VDC ~ 2.0 VDC
      High logic 2.8 VDC ~ 5.0 VDC
      Hysteresis 0.8 VDC
      Pullup fixed
   Power output 
      Connector (1) 3.5 mm captive screw connectors, 2 pole
provides power to transmitter
      Power output 14 VDC @ 100 mA
   Detecting Distance 10 feet (3.0 m)
   Operating angle Transmitter/Receiver 3-15 degrees
ECM S10 — Transmitter
   Light source Infrared LED (870 nm wavelength)
Software and control options
   Configuration software Global Configurator Plus and Professional
   Programming software Global Scripter
   Control apps Extron Control
   Utilities Toolbelt
General
   Power 
      Transmitter 14 VDC (supplied by ECM S10 receiver)
      Receiver 12 VDC (Power is supplied by an Extron IPCP Pro series control processor or optional power supply)
   Power consumption 1.0 watts (transmitter and receiver combined)
   Ambient temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 35% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 35% to 85%, noncondensing
   Cooling Convection, no vents
   Thermal dissipation 
      Transmitter TBD BTU/hr
      Receiver TBD BTU/hr
   Mounting 
      Rack mount No
      Furniture or wall mount Yes, in a standard 1-gang US, EU or MK junction box.
Oversized 1-gang Decorator style faceplate
   Enclosure type  Plastic faceplate, metal mounting plate
   Enclosure dimensions — Transmitter
      Faceplate (Transmitter and Receiver) Decorator style
4.50" H x 2.79" W (114 mm H x 71 mm W)
      Device  
         Transmitter 4.20" H x 1.75" W x 1.66" D (108 mm H x 45 mm W x 42 mm D)
         Receiver 4.20" H x 1.75" W x 2.46" D (108 mm H x 45 mm W x 63 mm D)
       
   Product weight  TBD lb (TBD kg)
   Regulatory compliance CE, c-UL, C-Tick, FCC Class A, ICES, RoHS, UL, VCCI class A, WEEE
   Product warranty 3 years parts and labor
    NOTE     All nominal levels are at ±10%.
    NOTE     Specifications are subject to change without notice.
(4500-D2)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-1705-03 2.75" (7.0 cm) 13.31" (33.8 cm) 9.13" (23.2 cm) 1.25 lbs (0.57 kg)

Diagram

ECM S10 Diagram

Panel Drawing

ECM S10 Panel Drawing